1
1

Demand for 95 high-voltage switchgears in two stations! The first bidding for substation equipment in Xiong'an New District in 2019 started

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2021-08-30
  • Views:0

(Summary description)The 19th National Congress of the Communist Party of China included high-start planning and high-standard construction of the Xiong'an New District in the report. 2018-2020 is a period of large-scale and concentrated construction of the Xiongan New District. The "Planning Outline of the Xiong'an New District, Hebei" proposes to strengthen the regional power supply and build a regional UHV power supply network. Renovate and upgrade existing substations, and build 500 kV and 220 kV substations. Actively introduce renewable energy such as wind power and photovoltaics as an important source of power supply in the new district. The reliability rate of power supply in the new district reaches 99.999%.

The planning and construction of the Xiongan New District will highlight seven key tasks: one is to build a green and smart new city, and build a world-class, green, modern, and smart city; the other is to create a beautiful ecological environment, and build a blue-green interweaving, fresh and bright, and water-city harmony. The third is to develop high-end high-tech industries, to actively absorb and gather innovative element resources, and to cultivate new kinetic energy; the fourth is to provide high-quality public services, build high-quality public facilities, and create a new model for urban management; fifth, to build a fast and efficient transportation network to create Green transportation system; Sixth, to promote the reform of the system and mechanism, give full play to the decisive role of the market in the allocation of resources and better play the role of the government to stimulate market vitality; Seventh, to expand all-round opening to the outside world, to create a new highland of opening up and a new platform for foreign cooperation.

As a result, the development of Xiongan New District has brought a golden historical opportunity for the development of enterprises and power grids.

According to media reports, Wang Hongzhi, director of the Development Planning Department of the State Grid Corporation of China, once introduced that the high-point positioning of the Xiongan New Area has put forward five requirements for the supporting role of the power grid: First, to ensure reliable power supply for high-end high-tech industries, it is necessary to speed up the UHV power grid. Construction, build a strong main grid, strengthen the construction of the distribution network, improve power supply capacity and power supply quality; second, in order to build a green and smart new city, it is necessary to widely apply communication and information technology, actively consume clean and renewable energy, and build a world-class green Smart grid; third, in order to create a beautiful ecological environment, it is necessary to build a green and low-carbon energy use system, increase the proportion of electric energy in terminal energy consumption, and improve energy efficiency; fourth, to provide high-quality public services, a modern power supply service system needs to be established to realize the grid User-friendly interaction and caring services; Fifth, in order to support the green transportation system, it is necessary to speed up the construction of electric vehicles, high-speed railways, and urban rail transit supporting power grids, build a vehicle networking platform, and ensure the energy use of green transportation.

Among them, it is particularly important to supplement and improve the construction of the main grid in the Xiongan New Area and to ensure the power support for the construction of the Xiongan New Area.

Recently, Polaris Power Transmission and Distribution Network was informed that the first tender for substation equipment in Xiong'an New District was opened in 2019. The bidding materials are mainly used for the new construction of the 220kV substation in Rongdong (Jucun) and the new construction of the 110kV substation in Hexi. The bidding materials mainly involve equipment such as high-voltage switchgear, transformers and combined electrical appliances.

Demand for 95 high-voltage switchgears in two stations! The first bidding for substation equipment in Xiong'an New District in 2019 started

(Summary description)The 19th National Congress of the Communist Party of China included high-start planning and high-standard construction of the Xiong'an New District in the report. 2018-2020 is a period of large-scale and concentrated construction of the Xiongan New District. The "Planning Outline of the Xiong'an New District, Hebei" proposes to strengthen the regional power supply and build a regional UHV power supply network. Renovate and upgrade existing substations, and build 500 kV and 220 kV substations. Actively introduce renewable energy such as wind power and photovoltaics as an important source of power supply in the new district. The reliability rate of power supply in the new district reaches 99.999%.

The planning and construction of the Xiongan New District will highlight seven key tasks: one is to build a green and smart new city, and build a world-class, green, modern, and smart city; the other is to create a beautiful ecological environment, and build a blue-green interweaving, fresh and bright, and water-city harmony. The third is to develop high-end high-tech industries, to actively absorb and gather innovative element resources, and to cultivate new kinetic energy; the fourth is to provide high-quality public services, build high-quality public facilities, and create a new model for urban management; fifth, to build a fast and efficient transportation network to create Green transportation system; Sixth, to promote the reform of the system and mechanism, give full play to the decisive role of the market in the allocation of resources and better play the role of the government to stimulate market vitality; Seventh, to expand all-round opening to the outside world, to create a new highland of opening up and a new platform for foreign cooperation.

As a result, the development of Xiongan New District has brought a golden historical opportunity for the development of enterprises and power grids.

According to media reports, Wang Hongzhi, director of the Development Planning Department of the State Grid Corporation of China, once introduced that the high-point positioning of the Xiongan New Area has put forward five requirements for the supporting role of the power grid: First, to ensure reliable power supply for high-end high-tech industries, it is necessary to speed up the UHV power grid. Construction, build a strong main grid, strengthen the construction of the distribution network, improve power supply capacity and power supply quality; second, in order to build a green and smart new city, it is necessary to widely apply communication and information technology, actively consume clean and renewable energy, and build a world-class green Smart grid; third, in order to create a beautiful ecological environment, it is necessary to build a green and low-carbon energy use system, increase the proportion of electric energy in terminal energy consumption, and improve energy efficiency; fourth, to provide high-quality public services, a modern power supply service system needs to be established to realize the grid User-friendly interaction and caring services; Fifth, in order to support the green transportation system, it is necessary to speed up the construction of electric vehicles, high-speed railways, and urban rail transit supporting power grids, build a vehicle networking platform, and ensure the energy use of green transportation.

Among them, it is particularly important to supplement and improve the construction of the main grid in the Xiongan New Area and to ensure the power support for the construction of the Xiongan New Area.

Recently, Polaris Power Transmission and Distribution Network was informed that the first tender for substation equipment in Xiong'an New District was opened in 2019. The bidding materials are mainly used for the new construction of the 220kV substation in Rongdong (Jucun) and the new construction of the 110kV substation in Hexi. The bidding materials mainly involve equipment such as high-voltage switchgear, transformers and combined electrical appliances.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2021-08-30
  • Views:0

The 19th National Congress of the Communist Party of China included high-start planning and high-standard construction of the Xiong'an New District in the report. 2018-2020 is a period of large-scale and concentrated construction of the Xiongan New District. The "Planning Outline of the Xiong'an New District, Hebei" proposes to strengthen the regional power supply and build a regional UHV power supply network. Renovate and upgrade existing substations, and build 500 kV and 220 kV substations. Actively introduce renewable energy such as wind power and photovoltaics as an important source of power supply in the new district. The reliability rate of power supply in the new district reaches 99.999%.

The planning and construction of the Xiongan New District will highlight seven key tasks: one is to build a green and smart new city, and build a world-class, green, modern, and smart city; the other is to create a beautiful ecological environment, and build a blue-green interweaving, fresh and bright, and water-city harmony. The third is to develop high-end high-tech industries, to actively absorb and gather innovative element resources, and to cultivate new kinetic energy; the fourth is to provide high-quality public services, build high-quality public facilities, and create a new model for urban management; fifth, to build a fast and efficient transportation network to create Green transportation system; Sixth, to promote the reform of the system and mechanism, give full play to the decisive role of the market in the allocation of resources and better play the role of the government to stimulate market vitality; Seventh, to expand all-round opening to the outside world, to create a new highland of opening up and a new platform for foreign cooperation.

As a result, the development of Xiongan New District has brought a golden historical opportunity for the development of enterprises and power grids.

According to media reports, Wang Hongzhi, director of the Development Planning Department of the State Grid Corporation of China, once introduced that the high-point positioning of the Xiongan New Area has put forward five requirements for the supporting role of the power grid: First, to ensure reliable power supply for high-end high-tech industries, it is necessary to speed up the UHV power grid. Construction, build a strong main grid, strengthen the construction of the distribution network, improve power supply capacity and power supply quality; second, in order to build a green and smart new city, it is necessary to widely apply communication and information technology, actively consume clean and renewable energy, and build a world-class green Smart grid; third, in order to create a beautiful ecological environment, it is necessary to build a green and low-carbon energy use system, increase the proportion of electric energy in terminal energy consumption, and improve energy efficiency; fourth, to provide high-quality public services, a modern power supply service system needs to be established to realize the grid User-friendly interaction and caring services; Fifth, in order to support the green transportation system, it is necessary to speed up the construction of electric vehicles, high-speed railways, and urban rail transit supporting power grids, build a vehicle networking platform, and ensure the energy use of green transportation.

Among them, it is particularly important to supplement and improve the construction of the main grid in the Xiongan New Area and to ensure the power support for the construction of the Xiongan New Area.

Recently, Polaris Power Transmission and Distribution Network was informed that the first tender for substation equipment in Xiong'an New District was opened in 2019. The bidding materials are mainly used for the new construction of the 220kV substation in Rongdong (Jucun) and the new construction of the 110kV substation in Hexi. The bidding materials mainly involve equipment such as high-voltage switchgear, transformers and combined electrical appliances.

Related news

What

What are the measures to prevent oxidation of the contacts of high-voltage circuit breakers?

Due to the frequent operation of high-voltage circuit breakers, they often fail to trip due to mechanical and electrical factors. For the circuit breaker that has been put into operation, when the fault reappears on the load side of the circuit breaker, once a refusal trip occurs, it will inevitably cause skipping trips, expanding the scope of accidents and power outages, so it should be eliminated as soon as possible. The measures to reduce contact resistance and prevent contact oxidation are as follows: (1) Use materials with low resistivity and compressive strength to make contacts. (2) Use springs or spring pads to increase the pressure between the contact surfaces. (3) Plating a protective layer of tin, lead-tin alloy or silver on the surface of the easily oxidized copper, brass, and bronze contacts to prevent the contact resistance from increasing due to the oxidation of the contacts. (4) Coat the surface of the aluminum contact with a neutral petroleum jelly layer to prevent oxidation to cover it. (5) Use welded copper-aluminum transition joints. (6) In the structure of the breakable contact, there is a certain relative sliding between the moving and static contacts, and the oxide layer can be wiped off when opening and closing (called self-cleaning effect) to reduce contact resistance. DHL-100P intelligent loop resistance tester is based on the Ministry of Electric Power standard SD301-88 "AC 500KV Power Equipment Handover and Preventive Test Regulations" and the new version of "Power Equipment Preventive Test Regulations" to make contact resistance of circuit breakers and isolating switches. The measured DC current is not less than 100 as specified to ensure the accuracy of the test results. The loop resistance tester adopts the latest switching power supply technology, which can continuously output large current for a long time, overcomes the shortcomings of the pulsed power supply's instantaneous current, can effectively break down the switch contact oxide film, and obtain good test results.
2021-08-30
Reasons

Reasons and treatment methods of high-voltage circuit breaker refusal to trip

Due to the frequent operation of high-voltage circuit breakers, they often fail to trip due to mechanical and electrical factors. For the circuit breaker that has been put into operation, when the fault reappears on the load side of the circuit breaker, once a refusal trip occurs, it will inevitably cause skipping trips, expanding the scope of accidents and power outages, so it should be eliminated as soon as possible. 1. Reasons for circuit breaker refusal to trip There are usually two reasons why the circuit breaker refuses to trip: one is the failure of the mechanical part of the operating mechanism, and the other is the electrical failure of the operating circuit. When the circuit breaker refuses to trip, the person on duty should first judge whether the trip circuit is intact according to the light indication. If the red light does not light up, it means that the trip circuit is blocked. At this time, check whether the operating fuse is blown or poorly contacted, whether the contact of the universal transfer switch and the auxiliary contact of the circuit breaker are poorly connected, whether the coil of the anti-trip relay is broken, whether the operating circuit is broken, whether the bulb or lamp is broken Wait intact. If the operating power is good and the tripping core is weak, it means that the tripping coil's operating voltage is too high, or the operating voltage is too low, the tripping core is jammed or detached, or the tripping coil itself is faulty. If the tripping iron core ejector rod is well transported and the circuit breaker refuses to trip, it may be that the mechanism is jammed or the drive connecting rod pin is detached. 2. Handling method for circuit breaker refusal trip After the reasons for the refusal to jump are ascertained, the personnel on duty should be calm and calm and adopt different solutions according to the nature of the failure. If the red signal light does not light up during the normal opening operation, after confirming that the lamp is in good condition, the operating fuse should be quickly replaced before the opening operation. At this time, it should be carried out by two persons, one person operating the change-over switch remotely, and the other person observing the action of the opening iron core on the spot, while keeping a safe distance. If the action of the iron core is weak, the iron core is blocking; if the opening iron core is operating normally, but the circuit breaker cannot be tripped, it means that the mechanical anti-jamming is indicated. At this time, a mechanical opening device should be used to interrupt the circuit breaker on the spot. For air circuit breakers and SF6 circuit breakers, the air pressure must be normal before the mechanism can be interrupted. When it is necessary to open the circuit breaker in an emergency situation, such as the operation of the relay protection device or the manual remote opening of the circuit breaker refused to open, which may cause damage to the main equipment, the person on duty should immediately open the upper-level circuit breaker manually, and then go to Use a mechanical opening device to interrupt the circuit breaker at the fault circuit breaker; if the mechanical opening device cannot open the circuit breaker, you should quickly open the isolation switches on both sides of the fault circuit breaker, and then restore the upper-level power supply. The cause is to be found out. Deal with it again; if the time permits in the accident state, the personnel on duty should quickly run to the fault circuit breaker and use a mechanical opening device to disconnect the circuit breaker; if the mechanical opening device cannot be used to open the circuit breaker, the operation mode should be changed immediately, or Use the bus tie circuit breaker and the upper-level circuit breaker to disconnect, and then use the isolating switch to isolate the fault circuit breaker and restore the operation mode. Therefore, it is recommended to use the DGK-S high-voltage switch dynamic characteristic tester to test the high-voltage circuit breaker on a regular basis in order to eliminate the fault in time. DGK-S high-voltage switch dynamic characteristic tester is a special high-voltage switch developed and produced by Dingsheng Electric Power Research and Development Center to adapt to the dynamic characteristics of various indoor and outdoor oil-less, multi-oil switches, vacuum switches, and sulfur hexafluoride switches. Dynamic characteristic tester, the internal processing of DGK-S high-voltage switch dynamic characteristic tester is based on the single-chip microcomputer as the core for sampling, processing and output. Its main function is to use Chinese character prompts and graphic displays to operate in a man-machine dialogue mode, which is simple and fast. It is suitable for testing the mechanical characteristics of all types and voltage levels of SF6 switches, GIS combined electrical appliances, vacuum switches, an
2021-08-30
Key

Key Technology of Intelligent High Voltage Switchgear

High-voltage switchgear refers to indoor and outdoor AC switchgear operating in power systems with a voltage of 3kV and above and a frequency of 50Hz and below. Mainly used for the control and protection of power systems (including power plants, substations, transmission and distribution lines, industrial and mining enterprises and other users). It can not only put part of power equipment or lines into or out of operation according to the needs of grid operation, but also can be used in power equipment or When the line fails, the faulty part is quickly removed from the power grid, so as to ensure the normal operation of the fault-free part of the power grid and the safety of equipment, operation and maintenance personnel. Therefore, high-voltage switchgear is a very important power transmission and distribution equipment, and its safe and reliable operation is of great significance to the safe and effective operation of the power system.
2021-08-30
Don't

Don't confuse a high-voltage switchgear with a transformer

"Box-type substation" is the abbreviation of box-type substation, also called prefabricated substation or prefabricated substation. It is a kind of high-voltage switchgear, distribution transformer and low-voltage power distribution device. It is a factory-prefabricated indoor and outdoor compact power distribution equipment arranged according to a certain wiring plan. It combines the functions of transformer step-down and low-voltage power distribution Together. It is installed in a moisture-proof, rust-proof, dust-proof, rodent-proof, fire-proof, anti-theft, heat-insulating, fully enclosed, and movable steel structure box. It is especially suitable for urban network construction and transformation. It is a kind of emerging after civil substation. Brand new substation. The box-type substation is suitable for mines, factories and enterprises, oil and gas fields and wind power stations. It replaces the original civil power distribution rooms and power distribution stations and becomes a new type of complete power distribution device. The box substation includes high-voltage incoming and outgoing lines, metering devices, transformers, low-voltage incoming lines, low-voltage power distribution outgoing lines, and other “combined” equipment, which is equivalent to a complete substation. But box-type substations are usually installed outside the building, so there are no special requirements for the selection of transformers, and oil-immersed transformers are generally used. What is a transformer? Dry-type transformer: It is only a kind of transformer, because the heat dissipation of the dry-type transformer winding is natural heat dissipation or forced air cooling (using a fan to force air convection), and there is no flammable and explosive substances, so it is widely used in places with relatively high requirements. , Such as a basement in a building. Unlike the oil-immersed transformer, which uses the convection of the transformer oil to dissipate heat, the transformer oil may be burnt in the event of an accident or if it leaks. Generally, it cannot be installed directly in the above-mentioned places.
2021-08-30